"HEPA" appears on everything from $80 bedroom purifiers to commercial containment scrubbers, and it does not always mean the same thing. If you are buying an air scrubber for mould, dust or odour work, it pays to know what the rating actually covers and what it does not.
What HEPA means
HEPA stands for high-efficiency particulate air. A HEPA filter is a pleated mat of very fine, randomly arranged fibres, usually glass fibre. Particles are captured in three main ways:
- Impaction: larger particles cannot follow the airflow around a fibre and hit it.
- Interception: mid-sized particles following the airflow brush against a fibre and stick.
- Diffusion: very small particles bounce around randomly and collide with fibres.
Because of those overlapping mechanisms, a HEPA filter is least efficient at one particular size, somewhere in the range of roughly 0.1 to 0.3 microns. That size is called the most penetrating particle size (MPPS). Particles both larger and smaller are caught more easily. This is why a filter rated at its weakest point is a meaningful rating.
Two ways of rating HEPA
You will see two different kinds of claims on spec sheets, and they come from different systems.
The European classes: H13 and H14
The European standard EN 1822 grades filters by their efficiency at the MPPS for that particular filter:
| Class | Minimum efficiency at MPPS | Maximum penetration |
|---|---|---|
| H13 | 99.95% | 0.05% (5 in 10,000 particles) |
| H14 | 99.995% | 0.005% (5 in 100,000 particles) |
The difference looks small but it is a factor of ten in what gets through. For most restoration, mould remediation and construction dust work, H13 is the common specification on portable scrubbers. H14 is more often specified in cleanrooms, some healthcare settings and critical containment.
The US definition: 99.97% at 0.3 microns
The other common claim, "99.97% of particles at 0.3 microns", comes from the US definition of HEPA. It tests at a fixed 0.3 micron size rather than each filter's own MPPS. Both approaches describe high-performance filters, but the numbers are not directly interchangeable. When comparing units, check which system a figure refers to and whether it describes the filter media alone or the complete machine.
The filter stack in a restoration scrubber
A HEPA filter should never be the first thing the air meets. A typical scrubber filter stack looks like this:
- Pre-filter (G4). A coarse filter that catches dust, lint, hair and plasterboard debris. G4 is a class from the older EN 779 system and is still widely used on spec sheets (the newer ISO 16890 system classifies coarse filters differently). The pre-filter is cheap and sacrificial. Its job is to protect the HEPA.
- Optional carbon stage. Activated carbon adsorbs gases, odours and volatile organic compounds (VOCs) that pass straight through a particulate filter.
- HEPA filter. The main particulate stage.
Thorair's 500 CFM HEPA air scrubber uses a G4 pre-filter and an H13 HEPA filter. The Hulk 1000 CFM scrubber uses four-stage filtration built around a G4 pre-filter and H13 HEPA.
Activated carbon: what it does and doesn't do
HEPA filters capture particles, including mould spores, fine dust and smoke particles. They do not remove gases. The musty smell of a mouldy room, sewage odours, smoke odour after a fire, and fumes from paint and solvents are largely gases and vapours.
Activated carbon has a huge internal surface area that holds these molecules. Useful points to know:
- Carbon is not a HEPA substitute. Use it alongside the HEPA stage, not instead of it.
- Carbon fills up. Once its surface is saturated it stops working, often without any visible sign. Heavy odour jobs use it up faster.
- Carbon deals with airborne odour, not the source. Remove the contaminated material and clean surfaces, or the smell keeps coming back.
For Thorair scrubbers, the HEPA/activated carbon filter (400 × 400 × 20 mm) suits the Pro HEPA scrubber, and there is a dedicated carbon filter for the 500 CFM scrubber for VOC, smoke and odour work.
Sealing: the part people forget
A filter rated at 99.95% is irrelevant if air leaks around it. Bypass leakage through a poor gasket, a warped frame or a filter seated crooked lets unfiltered air straight through the machine.
- Check the gasket every time you change or inspect a filter. Replace filters with damaged or compressed gaskets.
- Make sure the filter sits square in its housing and that the clamps or door close evenly.
- Never trim, fold or tape a filter to make it fit a different machine.
- Handle HEPA filters by the frame. Pleats are easily punctured, and a small tear can undo the rating.
When to change filters
There is no fixed timetable, because loading depends on the job. Demolition dust loads a pre-filter in hours; a clean office might take weeks. Practical signs:
- Pre-filter: check it daily on active jobs. Replace it when visibly loaded or when airflow drops. Changing pre-filters often is the cheapest way to extend HEPA life.
- HEPA filter: replace it when airflow stays low with a fresh pre-filter fitted, when it is damaged or wet, or when the unit's indicator (if fitted) says so. Many operators also fit a fresh HEPA before moving a scrubber from a mould or sewage job to a clean job.
- Carbon: replace it when odour control drops off.
Change filters inside containment or outdoors, away from clean areas. Bag used filters immediately in heavy-duty plastic, and wear a suitable respirator and gloves. Filters from mould and Category 3 water jobs should be treated as contaminated.
Keep spares on the van. A replacement Hulk primary filter (406 × 406 × 155 mm) and pre-filters for each scrubber model take up little space and save a return trip. You will find the full range under accessories.