Power is often the cost restorers think about least, and property owners ask about most. Whether you are quoting a job, explaining an electricity bill to a client or deciding between machines, the method is the same.
The formula
Running cost = power draw (kW) × hours running × tariff ($ per kWh)
Each part needs a little care.
Power draw
Find the unit's power figure on its rating plate (the compliance label on the back or side) or in the manual. It may be listed in watts (W) or as a current in amps (A). To convert:
- Watts to kilowatts: divide by 1,000. So 800 W is 0.8 kW.
- Amps to kilowatts: multiply by the supply voltage (about 230–240 V in Australia) and divide by 1,000. That gives an upper estimate, because the plate figure is usually the maximum.
A refrigerant dehumidifier does not draw its full rated power every hour of the day. The compressor cycles off when the humidistat target is reached, and it pauses during defrost cycles in cool rooms. On a wet job in the first few days, though, expect it to run close to continuously.
Hours running
On a structural drying job, equipment usually runs 24 hours a day. For ongoing humidity control in a storeroom or basement, a humidistat or timer might cut that to a few hours a day.
Tariff
Your electricity rate is on your bill as cents per kWh. Rates vary by state, retailer, plan and time of day, and many plans also charge a daily supply fee that you pay regardless. Always use your own figure.
A worked example
The numbers below are illustrative. The power figure is an assumption for the example, not a published Thorair specification. Check the rating plate on your own unit and use your own tariff.
Assumptions
- Dehumidifier average draw: 0.8 kW (example only)
- Running: 24 hours a day
- Tariff: an example rate of 35c/kWh (check your own bill)
Daily cost: 0.8 kW × 24 h = 19.2 kWh. 19.2 kWh × $0.35 = about $6.72 per day.
Four-day job: 4 × $6.72 = about $26.90.
If the compressor only runs 70% of the time once the room dries out, daily use falls to about 13.4 kWh, or roughly $4.70 a day at the same example rate.
Adding the rest of the equipment
Dehumidifiers rarely work alone. Air movers and scrubbers add to the bill, and for these Thorair does publish figures:
- The Pro Square blower is listed at 160 W on high. At 24 hours and the example 35c rate, that is 3.84 kWh, or about $1.34 a day.
- The Pro Snail carpet blower is listed at 550 W, which works out to about $4.62 a day under the same assumptions.
- The 500 CFM HEPA air scrubber is listed at 200 W, or about $1.68 a day.
So a room with one dehumidifier and three square blowers might use around 31 kWh a day, or roughly $10.75 at the example rate. Scale that up for a whole house and you can see why it is worth giving clients an estimate before they get the bill. For how many air movers a room needs, see how many air movers per room.
Why a faster finish usually costs less
The biggest lever on running cost is not the wattage, it is the number of days. A setup that finishes in three days almost always costs less in power than one that drags on for six, even if it draws more per hour.
This is where LGR dehumidifiers earn their place. A conventional refrigerant unit tends to stall as the air dries, so the final stretch of a job takes longer. An LGR unit keeps removing water at lower humidity, which helps dense materials such as timber and subfloors reach dry standard sooner. The full explanation is in LGR vs refrigerant vs desiccant dehumidifiers.
Getting the equipment count right from day one matters too. Too few dehumidifiers and the air stays wet, too few air movers and materials dry slowly. Either way, every machine runs longer. The dehumidifier size calculator gives a starting point, and daily moisture readings tell you when to adjust.
Other running costs to allow for
Drainage and pumps
On a multi-day job, a tank that fills overnight stops the dehumidifier and wastes a day. Run a continuous drain hose to a sink, shower or floor waste instead. The Pro LGR 50L has a continuous drain outlet, and a 7.5 m dehumidifier hose extends the reach. Where there is no drain lower than the unit, a condensate pump lifts water to a higher outlet; it adds a small power draw and one more part to check each visit.
Filter cleaning
A clogged intake filter cuts airflow, which means less air across the coil and less water removed for the same power. Check and clean washable filters at every monitoring visit on dusty or post-flood jobs, and at regular intervals for machines on long-term humidity control.
Coil and general care
Dust and debris on the coils reduce efficiency over time. Keep units clean between jobs, store them upright and check drain lines for kinks or blockages.
Heat in the room
Dehumidifiers and air movers release heat. In a sealed room this often helps drying, but in summer it can push temperatures up. Monitor temperature along with humidity, and do not open windows to cool the space unless the outdoor air is drier than the air inside.
Quick checklist for estimating a job
- List every machine and its rated watts from the rating plate.
- Multiply by 24 hours for drying jobs (or expected hours for humidity control).
- Multiply by the client's tariff.
- Multiply by your expected drying days, then allow a margin for longer jobs.
- Explain to the client that daily readings, not the calendar, set the finish date.